TM 5-5420-226-20-3
MASTER CONTROL PANEL REPAIR (Sheet 37 of 73)
Circuit Breaker Replacement (Sheet 5 of 7)
REMOVAL; CIRCUIT BREAKER (F):
1.
Using flat-tip screwdriver on screw
(A) and 11/32 inch wrench on nut (B),
(C), and nuts (B) securing connector
(D) to panel.
2.
Remove connector (D) from panel and
position aside.
Using fingers, remove two electrical
connectors from rear of circuit breaker
(E) by pulling out.
Using cross-tip screwdriver, remove
4.
securing circuit breaker (E) to panel.
Remove circuit breaker(E).
5.
Go on to Sheet 6
TA168725