3.14.2.10 Remove the retaining clips (2) and the pins (3) and disconnect the wire retention cable (4)
from the bottom of the crane stabilizer legs (1). Refit the pins and retaining clips.
3.14.2.11 Put the crane stabilizer spreader pads in position centrally below each crane stabilizer leg
and make sure the area around the crane stabilizer legs is clear of personnel.
3.14.2.12 Operate the crane controls on
the crane to
lower the crane stabilizer legs to
the ground.
3.14.2.13 Make sure the hydraulic cylinders extend and position the feet of the crane stabilizer legs
centrally on the crane stabilizers spreader pads.
3.14.2.14 Continue to independently operate the controls of the stabilizer leg on the low side of the
vehicle and raise the leg until the level on the crane legs indicates the crane is horizontally
NOTE
The last operation must be to extend the stabilizer leg, this operation electrically locks the
hydraulic pressure in the stabilizer leg.