TM-5-5420-279-10
Table 8.5 Operators PMCS (After) - (continued)
Location
Not Fully Mission
Item
Item to
Procedure
Interval
Capable If:
No.
Check
Service
3
2
1
148
After
A-frame
Check the A-frame upper and lower
Damage evident.
upper and
cross members, for damage.
lower
cross
members
149
After
A-frame
(a) Check A-frame lower cross member
lower
hydraulic pipes (1) for:
cross
(1) Damage.
Damage evident.
member
hydraulic
(2) Cracks in flexible pipes.
Cracks evident.
system
(3) Hydraulic fluid leaks.
Class III leak evident.
(b) Check A-frame lower cross member
hydraulic cylinders (2) for:
(1) Damage.
Damage evident.
(2) Hydraulic fluid leaks.
Class III leak evident.
(c) Check A-frame lower cross member
hydraulic control valves (3) for:
(1) Damage.
Damage evident.
(2) Hydraulic fluid leaks.
Class III leak evident.
8-49