TM-5-5420-279-10
Table 9. 1 Operators Panel MIMIC (continued)
Light
Indicator
Notes
Checks of Non Normal Status
Normal
Status
Controller Status Sub Panel
Launcher
ON
Interface enclosure
Fault with interface enclosure controller.
Controller
controller is functioning
Report to maintenance.
Healthy
correctly.
Bridge
ON
Launch frame electrical
Four position switch in cab at position 4 and
Controller
control enclosure
bridge build select sequence complete.
Healthy
controller is functioning
correctly.
Fault with interface enclosure controller.
Report to maintenance.
Rotate Closed On only Illuminates when the A-
Check LED on plug of SV19a (Refer to
SV19a
when
frame ROTATE PARK
button is operated.
when button is pushed, if LED does not
SV19a
is
illuminate report to maintenance.
powered
Rotate Open
On only
Illuminates when the A-
Check LED on plug of SV19b (Refer to
SV19b
when
frame ROTATE DEPLOY
button is operated.
when button is pushed, if LED does not
SV19b
is
illuminate report to maintenance.
powered
Fold Open
On only
Illuminates when the A-
Check LED on plug of SV20a (Refer to
SV20a
when
frame FOLD DEPLOY
button is operated.
when button is pushed, if LED does not
SV20a
is
illuminate report to maintenance.
powered
Fold Closed
On only
Illuminates when the A-
Check LED on plug of SV20a (Refer to
SV20b
when
frame FOLD PARK
button is operated.
when button is pushed, if LED does not
SV20b
is
illuminate report to maintenance.
powered
Breaker Resets
Vehicle
OFF
On when CB tripped.
Supply
AUX PTO
OFF
On when CB tripped.
Reset relevant CB ONCE, if fault persists (CB
Controller
OFF
On when CB tripped.
trips again) report to maintenance.
Launcher
OFF
On when CB tripped.
Deployment
Crane
OFF
On when CB tripped.
continued
9-5