TM-5-5420-279-10
Table 9. 1 Operators Panel MIMIC (continued)
Light
Indicator
Notes
Checks of Non Normal Status
Normal
Status
Breaker Resets (continued)
Tail lift
OFF
On when CB tripped.
Bridge
OFF
On when CB tripped.
Deployment
PTO
OFF
On when CB tripped.
Bridge Build Select Sub Panel
Launcher
ON
Only after four position
Check the four position switch in cab is in
Deploy
switch in cab is in position
position 2.
2 and A-frame is
deployed.
ON
Only as part of
Check the four position switch in cab is in
Programmable Logic
position 2.
Controller (PLC) setup
after four position switch
Check the tail lift hand set is connected.
in cab is in position 2 and
tail lift pendant is
Internal fault in interface enclosure report to
connected.
maintenance.
PTO Engaged
ON
On when PTO engages
Fault with the PTO hydraulic pump pressure
And At
and hydraulic pump is
switch report to maintenance.
Pressure
producing pressure.
Neutral Lock
ON
Fault with interface enclosure controller or
Up
neutral lockup.
vehicle ATEC shift control unit. Report to
maintenance.
Fast Idle
ON
Vehicle engine is set to
Fault with interface enclosure controller or
fast idle.
vehicle ATEC shift control unit. Report to
maintenance.
Tail lift Supply
ON
PLC in Operators Cabinet
Fault with interface enclosure controller.
has made power available
Report to maintenance.
to the tail lift.
Launcher
Power has been made
Rotate pins not in correct position.
Deployment
available to operate the A-
ON
frame fold and rotate
Fault with interface enclosure controller.
functions.
Report to maintenance.
continued
9-6