TM 5-5420-280-10
OPERATOR INSTRUCTIONS
RAPIDLY EMPLACED BRIDGE (REB)
OPERATION OF CBT BACK-UP POWER FOR BRIDGE LAUNCH OR RETRIEVAL
WARNING
Hydraulic oil may be hot. Exercise caution when
disconnecting pallet hydraulic supply hoses; wear gloves
and safety glasses. Failure to comply may result in injury
to personnel
CAUTION
CBT backup power should only be used when LPU is
inoperable. Use of CBT for continuous launch/retrieval
cycles will overheat CBT hydraulic pump and may result
in damage to equipment.
Prior to disconnecting/connecting hydraulic supply hoses,
clean debris from couplings and catch residual oil with
clean rags. Failure to comply may result in damage to
equipment.
1. Disconnect pallet hydraulic supply hoses (2) and (3) from pallet hydraulic
quick-disconnect couplings (1) and (4), located on A-frame adjacent to auxiliary
reservoir (5). Install dust cap (6) and plug (7) on quick-disconnect couplings (1)
and (4).
3
4
2
5
1
6
7