TM 5-5420-280-10
0030 00
MANUALLY BYPASSING SOLENOID DURING ELECTRIC POWER LOSS
(Contd)
WARNING
It may be necessary for operator to stand on fender
near exhaust to operate control valves. Exhaust system
will be hot. Keep clear of exhaust system or injury to
personnel may result.
3. Refer to and perform the appropriate operational procedures with the
following exceptions: when the procedure directs the operation of the remote
control unit or the cab controls, use the manual valve plunger tool (1), follow
the data plate under the cover, and perform the operation within the control
valve layout of the hydraulic manifold assembly. Fit plunger tool (1) in
appropriate hole in hydraulic manifold assembly (2) and press plunger
1
3
2
NOTE
Ensure PTO is off prior to removing free-flow valve tool.
4. Loosen thumbscrew (4) and remove free-flow valve tool from free-flow
valve (5). Close cover.
FREE-FLOW
VALVE TOOL
4
5
END OF WORK PACKAGE
0030 00-2