TM 5-5420-280-10
0041 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (Contd)
SPECIAL INSTRUCTIONS
Preventive maintenance is not limited to performing the checks and services
listed in the PMCS.
WARNING
Skysol 100 cleaning solvent is combustible. Use
mechanical ventilation whenever product is used in a
confined space, is heated above ambient
temperatures, or is agitated. DO NOT use or store
near heat, sparks, flame, or other ignition sources.
Keep container sealed when not in use.
Contact with Skysol 100 cleaning solvent may cause
skin irritation. Use chemical- resistant gloves. In case
of skin contact, remove any contaminated clothing
and wash skin thoroughly with soap and water. Wash
contaminated clothing before reuse. Eye contact may
cause irritation, tearing, or blurring of vision. Use
face shield or goggles when eye contact may occur. In
case of eye contact, flush eyes with large amounts of
water for at least fifteen (15) minutes or until
irritation subsides. Inhalation may cause irritation to
upper respiratory passages. DO NOT have food or
drink in the vicinity. Failure to comply may result in
injury to personnel.
WARNING
Compressed air source will not exceed 30 psi
(207 kPa). When cleaning with compressed air,
eyeshields must be worn. Failure to comply may
result in injury to personnel.
a. Keep it clean. Dirt, grease, oil, and debris get in the way and may cover up
a serious problem. Clean work area as needed. Use Skysol 100 on all metal
surfaces. Use soap and water to clean rubber or plastic material. Dry with
compressed air or clean, dry cloths. Refer to item 7, WP 0052 00.
b. Bolts, nuts, and screws. Check them all for obvious looseness, missing, bent,
or broken condition. Look for chipped paint, bare metal, or rust around bolt
heads; if loose, notify field maintenance.
c. Wiring harnesses, wires, and connectors. Look for cracked or broken wiring
harness insulation, bare wires, and loose or broken connectors. If faulty
wiring or loose connections are found, notify field maintenance.
0041 00-3