TM 55-1945-205-10-2
0041 00 3
0041 00
INSTALL LOUVER COVERS
1.
Install louver covers.
a.
Remove attaching bolts and washers from louver frame.
b.
Position louver cover over the generator container louver and align the open holes.
c.
Install bolts and washers through the open holes of the louver cover and the holes in the generator container
louver frame.
2.
Repeat steps to install second louver cover.
REMOVE GENERATOR CONTAINER GROUND CABLE
1.
Detach ground cable C-Clamp (8) from module ISO fitting (9).
2.
Remove nut (10), lock washer (11) and flat washer (12) from generator shelter ground stud (13).
3.
Remove ground cable (14) from generator shelter ground stud (13).
4.
Install flat washer (12), lock washer (11) and nut (10) on ground stud (13).
5.
Tighten nut (10).
6.
Detach power cable (15) from personnel shelter power receptacle (16).
7.
Close exterior hinged cover of the electrical shore tie and secure in the closed position.
8
9
14
13
10
11
12
16
15