TM 55-1945-205-24-20026 00 3/4 blank 0026 00MALFUNCTIONThe fan motor is defective.CORRECTIVE ACTIONReplace fan motor. (WP 0108 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-2)MALFUNCTIONThe fan blade or blower wheel is defective or stuck.CORRECTIVE ACTIONFree the fan blade or blower wheel by cleaning it. (WP 0105 00)Perform operational test on heating and air conditioning system. (TM 55-1945-205-10-2)MALFUNCTIONThe capillary tube and strainer are restricted or plugged.CORRECTIVE ACTIONClean or replace the capillary tube and strainer as required. (WP 0106 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-2)MALFUNCTIONThe system is overcharged.CORRECTIVE ACTIONService the air conditioning system. Contact depot maintenance.MALFUNCTIONThe system is undercharged.CORRECTIVE ACTIONService the air conditioning system. Contact depot maintenance.END OF WORK PACKAGE