INSTALL LIGHT TOWER BALLAST (cont) - TM-55-1945-205-24-2_481
INSTALL LIGHT TOWER CONTROL BOX PANEL
TM-55-1945-205-24-2 Modular Causeway System (MCS) Roll-On/Roll-Off Discharge Facility Model (RRDF) RRDF-1 NSN 1945-01-473-2282 Manual
Page Navigation
385
386
387
388
389
390
391
392
393
394
395
TM 55-1945-205-24-2
0163 00 1
0163 00
DIRECT SUPPORT MAINTENANCE
ROLL-ON/ROLL-OFF DISCHARGE FACILITY
LIGHT TOWER CONTROL BOX PANEL
REPLACEMENT
INITIAL SETUP:
Tools
Tool Kit, General Mechanic’s (Item 81, WP 0359 00)
Gloves, Men’s and Women’s (Leather Palm) (Item 27, WP 0359 00)
Goggles, Sun, Wind and Dust (Safety) (Item 29, WP 0359 00)
Helmet, Safety (Brown) (Item 33, WP 0359 00)
Life Preserver, Vest (Item 38, WP 0359 00)
Materials/Parts
Panel, Control Box
(33968)
PN 36876001
Personnel Required
Interior Electrician 51R
Equipment Condition
Light Tower Battery Negative Lead Terminal Removed. (WP 0134 00)
Light Tower Control Panel Hour Meter Removed. (WP 0147 00)
Light Tower Control Panel Fuel Gage Removed. (WP 0148 00)
Light Tower Control Panel Duplex Outlet Removed. (WP 0149 00)
Light Tower Control Panel Twist Lock Outlet. (WP 0150 00)
Light Tower Control Panel Main
Circuit Breaker
Removed. (WP 0151 00)
Light Tower Control Panel Toggle Switches Removed. (WP 0152 00)
Light Tower Control Panel 125 Volt Breaker Removed. (WP 0153 00)
Light Tower Control Panel Key Switch Removed. (WP 0154 00)
REMOVE LIGHT TOWER CONTROL BOX PANEL