TM 55-1945-205-24-40026 00 20026 00CORRECTIVE ACTIONClean and replace condenser and coil fins as required. (WP 0106 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-4)MALFUNCTIONCompressor system wiring is defective.CORRECTIVE ACTIONRepair/replace wiring as necessary. (WP 0248 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-4)MALFUNCTIONCompressor system has low voltage running to it.CORRECTIVE ACTIONUsing multimeter, check continuity between compressor motor black wire and other compressor wires. If continuity is not present, repair/replace wiring as necessary. (WP 0248 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-4)MALFUNCTIONThe system overload protector is defective.CORRECTIVE ACTIONTest the overload protector. (WP 0107 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-4)MALFUNCTIONThe system capacitor is defective.CORRECTIVE ACTIONReplace the capacitor. (WP 0108 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-4)