TM 55-1945-205-24-4
0026 00 1
0026 00
UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE
FLOATING CAUSEWAY
HEATING AND AIR CONDITIONING SYSTEM
TROUBLESHOOTING PROCEDURES
INITIAL SETUP:
Test Equipment
Multimeter (Item 30, WP 0253 00)
Personnel Required
Engineer 88L
Utilities Equipment Repairer 52C
References
TM 55-1945-205-10-4
TROUBLESHOOTING PROCEDURE
COMPRESSOR STARTS AND RUNS, BUT CYCLES ON THE OVERLOAD
SYMPTOM
Compressor runs, but cycles on the overload.
MALFUNCTION
Indoor air filter is dirty or plugged.
CORRECTIVE ACTION
Clean and replace the indoor air filter as required. (WP 0097 00)
Perform operational check on heating and air conditioning system.
(TM 55-1945-205-10-4)
MALFUNCTION
Vent air filter is dirty or plugged.
CORRECTIVE ACTION
Clean and replace the vent air filter as required. (WP 0099 00)
Perform operational check on heating and air conditioning system.
(TM 55-1945-205-10-4)
MALFUNCTION
The condenser and coil fins are dirty or plugged.