TM 55-1945-205-24-40027 00 20027 00MALFUNCTIONThe system capacitor is defective.CORRECTIVE ACTIONReplace the capacitor. (WP 0108 00)Perform operational test on heating and air conditioning system. (TM 55-1945-205-10-4)MALFUNCTIONThe fan motor is defective.CORRECTIVE ACTIONReplace fan motor. (WP 0105 00)Perform operational test on heating and air conditioning system. (TM 55-1945-205-10-4)MALFUNCTIONThe capillary tube and strainer are restricted or plugged.CORRECTIVE ACTIONClean or replace the capillary tube and strainer as required. (WP 0103 00)Perform operational test on heating and air conditioning system. (TM 55-1945-205-10-4)MALFUNCTIONAir is in the system.CORRECTIVE ACTIONService air conditioning system. Contact depot maintenance.MALFUNCTIONPressure in the system is not equalized.CORRECTIVE ACTIONService the air conditioning system. Contact depot maintenance.END OF WORK PACKAGE