TM 55-1945-205-24-4
0059 00 1
0059 00
UNIT LEVEL MAINTENANCE
FLOATING CAUSEWAY
COMBINATION BEACH/SEA END SECTION
NON-POWERED MODULE
INSPECTION FOR WATER
INITIAL SETUP:
Tools
Tool Kit, General Mechanics (Rail and Marine) (Item 54, WP 0253 00)
Gloves, Chemical (Item 14, WP 0253 00)
Goggles, Industrial (Chipping, Chemical) (Item 17, WP 0253 00)
Sling, 53,000 lbs (Brown) (Item 47, WP 0253 00)
Socket Wrench Set (Item 62, WP 0253 00)
Socket, Socket Wrench (Item 63, WP 0253 00)
Key, Socket Head Screw (Allen Wrench) (Item 64, WP 0253 00)
Materials/Parts
Antiseize Compound (Item 3, WP 0252 00)
Personnel Required
Seaman 88K
Equipment Condition
Combination Beach/Sea End Section Non-Powered Module Dry-Docked.
INSPECT COMBINATION BEACH/SEA END SECTION NON-POWERED MODULE
FOR WATER
NOTE
The following procedure is typical for inspecting non-powered modules for water and
machine plug location.
1.
Using breaker bar, socket and allen wrench, remove machine plug (1) from the module (2).
3
4
2
1
5