TM 55-1945-205-24-4
0072 00 1/2 blank
0072 00
UNIT LEVEL MAINTENANCE
FLOATING CAUSEWAY
GENERATOR CONTAINER 1,000 GALLON FUEL TANK FUEL LEVEL RELAY
REPLACEMENT
INITIAL SETUP:
Tools
Tool Kit, General Mechanics (Rail and Marine) (Item 54, WP 0253 00)
Personnel Required
Engineer 88L
Equipment Condition
Generator Shut Down. (TM 9-6115-642-10, TM 9-6115-643-10)
REMOVE GENERATOR CONTAINER 1,000 GALLON FUEL TANK FUEL LEVEL RELAY
NOTE
The following procedure is typical for the removal and installation of all fuel level relays.
1.
Remove four screws (1) from relay housing (2).
2.
Open door of housing (2) and locate defective relay (3).
3.
Remove relay (3) from socket (4) and discard.
INSTALL GENERATOR CONTAINER 1,000 GALLON FUEL TANK FUEL LEVEL RELAY
1.
Install new relay (3) into socket (4).
2.
Close door of housing (2).
3.
Install four screws (1) and tighten.
END OF WORK PACKAGE
2
3
4
1
2