TM 55-1945-205-24-4
0071 00 1
0071 00
UNIT LEVEL MAINTENANCE
FLOATING CAUSEWAY
GENERATOR CONTAINER 1,000 GALLON FUEL TANK FUEL LEVEL SENSORS
REPLACEMENT
INITIAL SETUP:
Tools
Tool Kit, General Mechanic’s (Rail and Marine) (Item 54, WP 0253 00)
Personnel Required
Engineer 88L
Equipment Condition
Generator
Shut Down. (TM 9-6115-642-10, TM 9-6115-643-10)
REMOVE
GENERATOR
CONTAINER 1,000 GALLON FUEL TANK FUEL LEVEL SENSORS
NOTE
The following procedure is typical for the removal and installation of all fuel level sensors.
1.
Remove nut (1) from elbow (2).
2.
Remove elbow (2) from sensor (3).
3
2
1