FUEL PUMP
INSTALL GENERATOR CONTAINER 1,000 GALLON FUEL TANK MANUAL FUEL PUMP - TM-55-1945-205-24-4_249
TM-55-1945-205-24-4 Modular Causeway System (MCS) Floating Causeway FC-1 NSN 1945-01-473-2162 Manual
Page Navigation
178
179
180
181
182
183
184
185
186
187
188
TM 55-1945-205-24-4
0074 00 2
0074 00
WARNING
2.
Disconnect hose (2) from fuel pump (1).
WARNING
3.
Drain residual diesel fuel from hose (2) into drain pan.
4.
Remove four hex head screws (3) from inlet flange (4).
WARNING
5.
Remove pump (1), inlet gasket (5) and screen (6) from inlet flange (4).
6.
Discard inlet gasket (5) and screen (6).