TM 55-1945-205-24-4
0159 00 2
0159 00
WARNING
All personnel must wear personal flotation device, hard hat, safety shoes and gloves
during FC operations and maintenance. Failure to observe these precautions could
result in serious injury or death.
High voltage capacitors may hold a charge long after power is turned off. Always
discharge capacitors before preforming maintenance. Failure to discharge
capacitors could result in injury or death to personnel.
NOTE
The following procedure is typical for the removal and installation of all light tower ballasts.
1.
Tag and disconnect wires (1) to ballast (2) and capacitor (3).
2.
Cut tiedown straps (4) holding capacitor (3) to ballast box (5).
3.
Remove capacitor (3) from ballast box (5) and discard.
4.
Remove four bolts (6) from ballast box (5) and ballast (2).
5.
Remove ballast (2) from ballast box (5) and discard.
INSTALL LIGHT TOWER BALLAST
1.
Position new ballast (2) in ballast box (5).
2.
Install four bolts (6) into ballast (2) and tighten.
3.
Position new capacitor (3) against ballast box (5).
4.
Install tiedown straps (4) around capacitor (3) and tighten.
5
2
6
3
1
4
1