TM 55-1945-205-24-40207 00 10207 00DIRECT SUPPORT MAINTENANCEFLOATING CAUSEWAYLIGHT TOWER - TOWER SUPPORTREPLACEMENTINITIAL SETUP:ToolsTool Kit, General Mechanic’s (Item 53, WP 0253 00)Gloves, Men’s and Women’s (Leather Palm) (Item 16, WP 0253 00)Goggles, Sun, Wind and Dust (Safety) (Item 18, WP 0253 00)Helmet, Safety (Brown) (Item 20, WP 0253 00)Life Preserver, Vest (Item 25, WP 0253 00)Materials/PartsSupport, Tower(33968)PN 43210301Pin, Cotter(33968)PN 95928867Personnel RequiredEngineer 88LEquipment ConditionLight Tower Battery Negative Lead Terminal Removed. (WP 0131 00)Light Tower - Tower Assembly Removed. (WP 0208 00)REMOVE LIGHT TOWER - TOWER SUPPORTWARNINGAll personnel must wear personal flotation device, hard hat, safety shoes and gloves during FC operations and maintenance. Failure to observe these precautions could result in serious injury or death.1.Remove eight hex head bolts (1) and nuts (2) securing spring (3) and tower support (4) to front of light tower (5).