TM 5-5420-202-20-2
ENGINE OIL COOLER FLUID PUMP CONNECTOR REPLACEMENT (Sheet 3 of 4)
Remove and discard gasket (K) under
10.
connector (G).
C L E A N I N G AND INSPECTION:
Cleaning agent specified is flam-
mable. Use only in well ventilated
areas. Keep away from flames,
sparks, or heat. Do not smoke
while using. Prevent contact with
eyes, mouth, and/or skin. Wear
rubber gloves when performing
cleaning procedures.
1.
Using dry cleaning solvent, clean hose (E)
and connector (G).
2.
Replace connector (G) if cracked or
broken.
Inspect threads on hose (E) and connector
3.
(G). Replace as required.
4.
Replace hose (E) if woven shielding
is worn or broken.
INSTALLATION:
Position new gasket (A) on oil cooler
1.
(B).
2.
Position connector (C) over gasket
(A).
Using 1/2 inch wrench, install three
3.
new locknuts (D).
4.
Using 1-1/2 inch wrench install hose
(E) to connector (C).
Go on to Sheet 4