TM
5-5420-202-20-2
ACCELERATOR THROTTLE LINKAGE REPLACEMENT (Sheet 5 of 9)
Using pliers, remove cotter pin (AB) from straight pin (AC).
20.
21.
Remove straight pin (AC).
22.
Remove bellcrank lever (C).
23.
Using 1/2 inch wrench, loosen nut (AD).
NOTE
Count and write down number of turns needed to unscrew clevis (AE).
Unscrew clevis (AE) and nut (AD) from connecting link (Al?).
24.
C L E A N I N G AND INSPECTION:
T o prevent personal injury, wear
Dry cleaning solvent P-D-680 is toxic and flammable.
protective goggles and gloves and use only in a well-ventilated area. Avoid contact with skin,
eyes, and clothes and don't breathe vapors. Do not use near open flame or excessive heat. The
flash point for Type #1 Dry Cleaning Solvent is 100F (38C) and for Type #2 is 138F (50C).
If you become dizzy while using cleaning solvent, get fresh air immediately and get medical aid.
If contact with eyes is made, wash your eyes with water and get medical aid immediately.
Using dry cleaning solvent and clean cloths, clean all parts.
1.
Inspect all parts for bends, cracks, stripped threads, wear, or other defects. Replace
2.
d e f e c t i v e parts.
Go on to Sheet 6