TM 5-5420-202-20-3
MASTER CONTROL PANEL REPAIR (Sheet 68 of 73)
Master Control Panel Wiring Harness Replacement (Sheet 5 of 7)
INSTALLATION:
Position connector (A) onto panel.
1.
Using flat-tip screwdriver on screws (B)
2.
and wrench on nuts (D), install four
(D) to secure connector (A) to panel
(E).
3.
(F), flatwashers (G), and nuts (H)
securing two harness junctions (J) to
panel.
4.
Apply silicone compound to all male
electrical connectors of wiring harness
(K).
TA249046