INFRARED PERISCOPE CABLE REPLACEMENT (Sheet 5 of 6)
BASKET WIRING HARNESS DISCONNECT (Sheet 1 of 4)

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -3 Page Navigation
  369    370    371    372    373  374  375    376    377    378    379  
img
. .
TM 5-5420-202-20-3
INFRARED PERISCOPE CABLE REPLACEMENT (Sheet 6 of 6)
13.
Install cables (A) and (G) on I.R. power packs (T).
14.
Using wrench, tighten two nuts (U) to secure cables (A) and (G) to I.R. power packs (T).
15.
Install three ground straps at batteries (page 10-268).
16.
Install floor access cover under commander's periscope stowage box (page 17-7).
17.
Install commander's periscope stowage box (TM 5-5420-228-24).
End of Task