TM 5-5420-202-20-3
THRUST WASHER BEARING SEAL (OUTPUT FLANGE) (Sheet 1 of 2)
PROCEDURE INDEX
PAGE
PROCEDURE
Removal
Installation
Brass drift
7/8 in. socket with in. drive
TOOLS:
in. drive breaker bar
Mechanical puller
Diagonal pliers
Machinists hammer
Nonelectrical wire
SUPPLIES:
Wooden block
Grease (Item 38, Appendix D)
PRELIMINARY PROCEDURES:
REMOVAL:
Using diagonal pliers,
1.
remove nonelectrical wire (A)
from thrust washer bearing
screw (B).
2 . Using 7/8, inch socket and
breaker bar, remove screw (B),
washer (C) and flange (D).
3 . Using mechanical puller,
remove seal.
Go on to Sheet 2