INSTALLATION:
1. Mount ignition control assembly (A) to heater,
and install two screws and lockwashers (B).
2. Using screwdriver tighten four screws (B) to
secure ignition control (A) to heater.
3. Route lead (C) under heater solenoid
to terminal (N.O.) (D) on flame detector
switch (E).
4. Install screw and lockwasher (F) securing
lead (C) to flame detector switch.(E).
5. Using screwdriver, tighten screw (F).
6. Connect two leads (G) and (H) to ignition
control (A).
7. Install plastic band (J).
8. Install heater cover (page 18-9, steps 7
and 8).
9. Connect electrical connector (page 18-9,
steps 9 and 10).
10. Check heater operation (TM 5-5420-202-10)
End of Task