TM 5-5420-202-20-4
PERSONNEL HEATER AIR DUCT OUTLET HOSE AND DEFLECTOR REPLACEMENT
(Sheet 3 of 3)
Place clamp (J) in position on hose (B) and
5.
bracket (K).
Hold two nuts (L) with 9/16 inch wrench.
6.
Use 9/16 inch socket to install two screws
(J) to bracket (K).
Place deflector (P) in position on hose (B).
7.
Hold nut (Q) with 7/16 inch wrench. Use 7/16 inch socket to install screw (R), lockwasher
8.
(S), washer (T), and spacer (U) securing deflec tor (P) to bracket (K).
Using screwdriver, tighten clamp (A).
9.
TA248618
End of Task
18-19