TM 5-5420-202-20-4
INTERIOR RELEASE MECHANISM REPAIR (Sheet 2 of 11)
Using screwdriver, remove two screws
2.
(B). Separate retainer (H) from switch
assembly (D).
3.
Using finger, push down and, separate
switch guard (J) from retainer (H).
Using long nose pliers, remove
4.
antipilferage seal (K) from release
mechanism (C). Using pliers, remove
spring (L) from pawl (M) and release
mechanism (C).
Go on to Sheet 3
TA248687