TM 5-5420-202-20-4
INTERIOR RELEASE MECHANISM REPAIR (Sheet 6 of 11)
NOTE
Before installing new grommet (D) into
bracket (E), it will be necessary to place
grommet (D) in boiling water, using cook-
ing stove, for 2-3 minutes.
If grommet (D) was removed, using pliers
3.
and wearing rubber gloves, quickly
remove grommet (D) from boiling water
and snap it in place into bracket (E).
Position lever pin (F) partially into hole
4.
in left side of bracket (E).
5.
Position thrust washer (G), lever (H),
cam (J), lever (K), and another thrust
washer (G) onto lever pin (F).
6.
Push lever pin (F) through right hole of
bracket (E) so that both ends of pin (F)
are flush with outside of bracket (E).
Go on to Sheet 7
TA248691
20-33