TM 5-5420-202-34
POWER TAKEOFF REPAIR (Sheet 3 of 8)
Remove two jackscrews used in steps 6 and 7.
9.
Remove gasket (N) from adapter (M). Throw gasket away.
10.
11.
Using stud remover/installer, remove eight studs (L) from power takeoff housing (B)
and eight studs (H) from adapter (M).
12.
Using internal retaining ring pliers, remove retaining ring (P) from adapter (M).
13.
Using arbor press, support adapter (M) with gasket surface down and press shaft (Q) and
bearing (R) from adapter (M).
Position adapter (M) with gasket surface up on two pieces of wood, allowing clearance to
14.
drive seal (S) from cover.
15.
Using brass punch and hammer, remove seal (S) from adapter (M) by alternately driving seal
from side to side. Throw seal (S) away.
Go on to Sheet 4
3-16