TM 5-5420-202-34
POWER TAKEOFF REPAIR (Sheet 5 of 8)
CLEANING AND INSPECTION:
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable. To prevent personal
injury, wear protective goggles and gloves and use only in a well-ventilated
area. Avoid contact with skin, eyes, and clothes and don't breathe vapors.
Do not use near open flame or excessive heat. The flash point for Type #1
Dry Cleaning Solvent is 100F (38C) and for Type #2 is 138F (50C). If you
become dizzy while using cleaning solvent, get fresh air immediately and get
medical aid. If contact with eyes is made, wash your eyes with water and get
medical aid immediately.
1.
Using dry cleaning solvent, clean all parts of power takeoff assembly.
2.
Using putty knife, scrape all remaining gasket material from gasket surfaces.
3.
Check all parts and surfaces for cracks, damage, and/or wear.
ASSEMBLY:
1.
Position power takeoff housing (A) on bench with cover surface facing up.
2.
Position power takeoff housing bushing
(B) in housing (A) with bushing lubricating
hole alined with supply hole in housing
(A).
3.
Using brass punch and hammer, install
bushing (B) by driving it in until flange
of bushing (B) bottoms in housing (A).
4.
Position power takeoff housing (A) on
bench with fuel pump adapter surface
resting on bench.
5.
Install pinion drive gearshaft (C) into
power takeoff housing (A).
Go on to Sheet 6
3-18