TM 5-5420-202-34
TRANSMISSION REPLACEMENT (Sheet 11 of 23)
CLEANING:
Dry cleaning solvent P-D-680 is toxic and flammable. To prevent
personal injury, wear protective goggles and gloves and use only in a
well-ventilated area. Avoid contact with skin, eyes, and clothes and
don't breathe vapors. Do not use near open flame or excessive heat.
The flash point for Type #1 Dry Cleaning Solvent is 100F (38C) and
for Type #2 is 138F (50C). If you become dizzy while using cleaning
solvent, get fresh air immediately and get medical aid. If contact
with eyes is made, wash your eyes with water and get medical aid
immediately.
1.
Wearing rubber gloves, clean all parts that
have been removed from transmission with
dry cleaning solvent. Wipe dry with clean
rags.
2.
Using putty knife, clean all gasket material
from area where gaskets were removed.
INSTALLATION:
Using transmission sling (Item 4, Chapter
1.
2, Section I) and a
suitable hoist, remove
replacement transmission from container.
Remove shipping caps, plugs, covers,
2.
and mounts from replacement transmission
as components are installed and install
them on unserviceable transmission.
Using 3/4 inch wrench, install adapter
3.
(A) on transmission.
Using 3/4 inch wrench to hold adapter
4.
(A), use 7/8 inch wrench on nut (B) to
secure tube (C) to adapter (A).
Position new preformed packing (D),
5.
to transmission mounting flange.
Go on to Sheet 12
6-29