TM 5-5420-202-34
TRACK ADJUSTING LINK REPAIR (Sheet 11 of 13)
21.
Turn needle valve handle (M) counterclock-
wise until gage (AA) indicates zero psi,
then turn handle (M) clockwise until closed.
22.
Using 7/8 inch wrench, remove test fixture
plug (AB) from manifold block hole (W)
and return plug (AB) to its storage hole
(AC) in test fixture frame.
23.
Using 7/8 inch and 5/8 inch wrenches,
disconnect hose assembly (R) with adapter
(S) from relief valve hole (T) in adjusting
link yoke (C).
24.
Using 7/8 inch and 5/8 inch wrenches,
install hose assembly (R) with adapter
(S) in manifold block hole (W).
Go on to Sheet 12
9-39