TM 5-5420-203-14
NEAR-SHORE CENTER SECTION REPLACEMENT (Sheet 1 of 4)
TOOLS/EQUIPMENT:
General Mechanics Tool Box SC 5180-90-N26
Lifting Device (8000 lbs capacity)
Sling, Multiple Leg
None.
SUPPLIES:
EQUIPMENT CONDITIONS:
Scissoring Cables and attaching hardware removed (pg 3-20).
Center Section Transverse Braces removed (pg 3-37).
Five
PERSONNEL:
REMOVAL
REMOVE NEAR-SHORE CENTER SECTION (4 AND 7).
a. Remove four retaining pins (1) from four
locking and connecting pins (2). Remove four
locking and connecting pins (2) securing ramp
section (3) to center section (4).
b. Using lifting device, separate ramp section
(3) from adjoining center section (4) a
distance of about 1 ft.
c. Perform steps a. and b. for opposite ramp.
WARNING
FRH hydraulic fluid may contain Tricresyl
Phosphate (TCP) which, if taken internally,
can cause paralysis. Hydraulic fluid may be
absorbed through the skin. If hydraulic fluid
gets on skin, wash with soap and water as
soon as possible.
d. Disconnect flexible hydraulic line (5) from
separated ramp section (3). Position line (5)
out of harm's way.
e. Perform step d. for opposite ramp.