TM 5-5420-203-14
NEAR-SHORE CENTER SECTION REPLACEMENT (Sheet 2 of 4)
f. Using lifting device and sling, move separated
ramp section (3) aside,
g. Drive quadrant hinge pin (6) from center
hinges of center sections (4 and 7) from
the center outward.
h. Remove pin retainer (8) from connector pin
(9). Remove pin (9) from top connecting
point (10) of center sections (4 and 7).
i. Remove pin retainer (11) from center section
pin (12). Remove pin (12) from center sections
(4 and 7). Remove pin retainer (13) from
connector pin (14). Remove pin (14) from
connecting point (15) of center sections
(4 and 7).
j. Using lifting device and sling, separate center
section about 1 ft from adjoining center
section.
WARNING
FRH hydraulic fluid may contain
Tricresyl Phosphate (TCP) which, if
taken internally, can cause paralysis.
Hydraulic fluid may be absorbed
through the skin. If hydraulic fluid gets
on skin, wash with soap and water as
soon as possible.
k. Disconnect flexible hydraulic line (16) at
connection point located on center section
(4). Route line (16) out hose guide (17) and
remove from bracing of center section (4).
1. Position line (16) out of harm's way on center
section (4).