I
TM 5-5420-203-14
FAR-SHORE CENTER SECTION REPLACEMENT (Sheet 2 of 4)
f. Using lifting device and sling, move separated
ramp section (3) aside.
Drive quadrant hinge pin (6) from center
hinges of center sections (4 and 7) from the
center outward.
h. Remove pin retainer (8) from connector pin
(9). Remove pin (9) from top connecting
points (10) of center sections (4 and 7).
i. Remove pin retainer (11) from center section
pin (12). Remove pin (12) from center sections
(4 and 7). Remove pin retainer (13) from
connector pin (14). Remove pin (14) from
connecting point (15) of center sections
(4 and 7).
Using a lifting device and sling, separate
center section about 1 ft from adjoining center
section.
WARNING
FRH hydraulic fluid may contain
Tricresyl Phosphate (TCP) which, if
taken internally, can cause paralysis.
Hydraulic fluid may be absorbed
through the skin. If hydraulic fluid gets
on skin, wash with soap and water as
soon as possible.
k. Disconnect flexible hydraulic line (16) at
connection point located on center section
(4). Slide line (16) out of hose guide (17) and
remove from bracing of center section (4).
1. Position flexible hydraulic line (16) out of
harm's way on center section (7).
3-65