ARMY TM 5-5420-212-10-1MARINE CORPS TM 08676A-10/1-1TABLE 7-4. (cont’d) Delaunch Table - 2E + 18 through 2E + 22 Bay Link ReinforcedBridge ft138144150156162Length m42.143.945.747.649.42E+No. of Bays1819202122L/Nose6N1+3N26N1 +3N26N1+3N26N1+3N26N1+3N2V Distanceft148.8154.7160.6165.2168.8m45.3647.1648.9650.3651.45Boom1p21p21p21p21p2Remove777776,3N2**6,3N2**6,3N2**6,3N2**6,3N2**555554,6N1*4,6N1*4,6N1*4,6N1*4,6N1*3,23,23,23,23,2(CG)(Bp3)(Bp3)(Bp3)(Bp3)(Bp3)BoomBp2Bp2Bp2Bp2Bp2Remove1,E1,E1,E1,E1,EComplete by:Note gNote gNote gNote gNote gNOTES:a.Remove curbs, ramps and deck units and add counterweight if required.b.Position ex. FRB under bridge min.1.5 ft (0.5 m) from end.c.Add LNCG posts, LNCG, nose roller and install launching nose, then reposition LRP 12 ft from A peg.d.Delaunch bridge until far BSB is 6 ft (1.8 m) from A peg or end of ETP overhangs CRB by min. 1.5 ft (0.5 m)e.Reposition LRP against A peg and then remove ex. FRB.f.Stop boom/delaunch to remove long or short links, light tackle, anti-flutter and add launching noses asrequired, observing minimum 5 ft (1.5 m) overhang.g.Disassemble FRB and RRB. Clear site.**Remove double story launching nose.*Remove remainder of launching nose, LNCG, LNCG posts and nose roller.( )Center of gravity.7-9
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business