ARMY TM 5-5420-212-10-1MARINE CORPS TM 08676A-10/1-1(4)If pin cannot be removed by hand, hold drift pin (5) firmly against end of pin (2), then tap end of drift pinwith hammer until pin is free.(5)Remove pin (2) and resilient mount (3).b.Service/Repair(1)Clean pin with crocus cloth.(2)Clean holes in housing with crocus cloth.(3)Replace components that are damaged, distorted or bent.c.Installation(1)Hold resilient mount (1) in housing (2) and insert pin (3) until head of pin is fully seated against housing.(2)Push cotter pin (4) through hole in pin (3), and bend prongs around end of pin.NOTEResilient mount should rotate on pin (pin should not rotate in frame). If the pin is rotation inhousing, report to Unit Maintenance.8-11
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business