ENGINE OIL COOLER FLUID PUMP CONNECTOR REPLACEMENT - Continued
OIL COOLER VENT HOSES AND FITTINGS REPLACEMENT

M48A5 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 -2 Page Navigation
  98    99    100    101    102  103  104    105    106    107    108  
img
. . .
TM 5-5420-226 -20-2
ENGINE OIL COOLER FLUID PUMP CONNECTOR REPLACEMENT (Sheet 4 of 4)
5.
Using 1-1/2 inch wrench, install hose
(E) to fitting (F).
6.
Using screwdriver and 3/8 inch wrench,
install clamp (G) on hose (E) if removed
during disassembly.
7.
Position new sealing washer (H) over vent
hole.
8.
Using 9/16 inch wrench install vent bolt
(J) through washer (H).
9.
Using socket and torque wrench, tighten
drain valve (K) to a minimum of 150 lb-
in. (17 Nm). Do not overtighten.
10.
Perform ground hop (page 5-25). Run
engine at idle until oil temperature is
in normal operating range (TM 5-5420-
226-10).
11.
Check oil level, add oil as required (LO 5-
5420-226-12).
12.
Disconnect ground hop kit (page 5-25).
Install powerplant (page 5-14).
13.
End of Task
TA107529