TM 5-5420-226-20-2
AIR CLEANER OUTLET ELBOW REPLACEMENT (Sheet 2 of 2)
INSTALLATION:
Position new gasket (A) and elbow (B)
1.
onto studs on air cleaner.
Using socket, extension, and wrench,
2.
install 14 nuts (C) securing elbow
(B) to air cleaner. Tighten nuts (C)
to 35 lb-ft (47 N*m) using sequence
shown.
Repeat sequence tightening nuts (C)
3.
to 50 lb-ft (68 N-m)
4.
5.
End of Task
Change 2