AIR CLEANER CIRCUIT BREAKER REPLACEMENT
AIR CLEANER BLOWER FAN GROUND LEAD REPLACEMENT - Continued

M48A5 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 -2 Page Navigation
  290    291    292    293    294  295  296    297    298    299    300  
img
. .
TM 5-5420-226-20-2
AIR CLEANER BLOWER FAN GROUND LEAD REPLACEMENT (Sheet 1 of 2)
TOOLS:
7/16 in. socket with 1/2 in. drive
1/2 in. socket with 1/2 in. drive
Ratchet with 1/2 in. drive
10 in. extension with 1/2 in. drive
REFERENCE: TM 5-5420-226-10
NOTE
Removal of left or right blower
fan ground lead is the same. Left
side shown.
REMOVAL:
1.
Using 1/2 inch socket, remove 10
screws (A) and lockwashers (B)
securing cover (C). Remove cover
(c).
2.
Disconnect two connectors (D) from blower
leads (E).
3.
Using 7/16 inch socket, remove screw (F) and
two washers (G) securing ground lead (H) to
boss (J).
Go on to Sheet 2
TA107717
7-112