TM 5-5420-226-20-2
AIR CLEANER DOOR REPAIR (Sheet 1 of 3)
TOOLS:
9/16 in. combination box and open end wrench
Long round nose pliers
Hammer (or mallet)
Slip joint pliers
SUPPLIES:
Gasket
Cotter pins (3 required)
Goggles (Item 71, Appendix D)
Leather gloves (Item 68, Appendix D)
Loctite adhesive (Item 66, Appendix D)
Face shield (Item 69, Appendix D)
REMOVAL:
WARNING
To prevent screws from pulling out
of box and injuring personnel, a
minimum of 200 pounds must be
placed atop the door before at-
tempting to remove screws.
NOTE
If captive screws are used, t h e y
W i l l only be loosened and not
removed.
1.
Using wrench, remove three screws (A).
2.
Using long round nose pliers, pull three
cotter pins (B) out of three straight pins
(c).
3.
Remove flat washers (D).
4.
Using hammer, tap straight pins (C) free
of door hinges (E).
5.
Using slip joint pliers, pull three straight
pins (C) from door hinges.
6.
Lift door assembly (F) and remove it from
air cleaner housing (G).
Go on to Sheet 2
Change 2