FUEL-WATER SEPARATOR OPERATIONAL TESTS - Continued
FUEL-WATER SEPARATOR OPERATIONAL TESTS - Continued

M48A5 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 -2 Page Navigation
  432    433    434    435    436  437  438    439    440    441    442  
img
FUEL-WATER SEPARATOR OPERATIONAL TESTS (Sheet 7 of 11)
15-Second Drain Test (Sheet 2 of 2)
WARNING
Do not let upper (E) and lower (F) sensor probes come
into direct contact with each other.
Do not let upper (E) or lower (F) sensor probes come
into contact with metal container (G).
Hold insulated cables (J) attached to upper (E) and
lower (F) sensor probes. Do not touch either probe.
6. Hold tips of both upper (E) and lower
(F) sensor probes in water in metal
container (G) until fluid stops draining
from solenoid drain valve drain tube (H).
7. If fluid does not stop draining from
solenoid drain valve drain tube (H) within
15 seconds from starting, refer to trouble-
shooting procedures ,
If fluid does stop draining, go to
8.
sequential drain test on next page.
9. Remove upper (E) and lower (F)
sensor probes from metal con-
tainer (G).
Go on to Sheet 8