TM 5-5420-228-24
HEU DEPRESSURIZATION MANIFOLD REPLACEMENT (Sheet 1 of 2)
PROCEDURE INDEX
Procedures
Page
Removal
Installation
TOOLS:
12-in. Adjustable wrench
1 3/8-in. open end wrench
9/16-in. socket with 1/2-inch drive
6-in. extension with 1/2-inch drive
11/16-in. open end wrench
15/16-in. open end wrench
SUPPLIES:
Drip pans (suitable containers)
Protective caps and plugs (assorted sizes)
Preformed packing (as required)
REFERENCE: LO-12
PRELIMINARY PROCEDURES:
REMOVAL:
NOTE
Use rags and drip pans to catch excess hydraulic fluid. Cap or plug all lines and
fittings as they are disconnected.
1.
Hold fitting (A) with adjustable wrench and use 11/16- inch wrench to disconnect hose "CB" (B) from fitting (A).
2.
Hold fitting (C) with adjustable wrench and use 15/16 inch wrench to disconnect hose "CD" (D) from fitting (C).
3.
Holding fitting (E) with adjustable wrench and use 15/16 inch wrench to disconnect hose "CE" (F) from fitting (E).
4.
Holding fitting (G) with adjustable wrench and use 1 3/8 inch wrench to disconnect hose "CC" (H) from fitting (G).
5.
Use socket, ratchet, and extension to remove four screws (J) and washers (K) from depressurization manifold
(L). Remove depressurization manifold (L).
6.
Position depressurization manifold (L) on a level surface and use adjustable wrench to remove fittings (A,C,E,G)
from manifold (L).
L
K
Go on to Sheet 2