TM 5-5420-228-24
RESERVOIR QUADRANT BLOWER MOTOR REPAIR (Sheet 3 of 4)
1.
Clean all metallic parts with rags and dry cleaning solvent.
Inspect all parts for damage and wear. Replace all unserviceable parts.
2.
ASSEMBLY:
1.
Using adjustable wrench, install pipe plug (A).
Place new gasket (B) and receptacle assembly (C) on commutator head (D).
2.
Using screwdriver, install four screws (E).
3.
Place new gasket (F) in position in commutator head (D).
4.
5.
Place capacitor (G), cable assembly (H), and leads of coil assembly (J) in position in
commutator head (D).
6.
Using screwdriver, install five screws (K) and lockwashers (L).
TA251658
Go on to Sheet 4