Table 1. Operator Preventive Maintenance Checks and Services (PMCS) for Improved Ribbon Bridge Ramp Bay (Contd).ITEM TONOT FULLYITEMCHECK/MISSIONNO.INTERVALSERVICEPROCEDURECAPABLE IF:TM 5-5420-278-100015 000015 00-1427BeforeRight stowagecompartmentlatches (3), lid (1), and BII (2)Check for loose, damaged, or missingmounting hardware, latches, and BII.(Refer to WP 0044 00 for Basic IssueItems required in ramp bay stowagecompartments.)Lid and latches areloose, will not close,or are missing. BIIare missing.12328BeforeRight outerponton side skinsurface (4)Check for structural damage.Puncture, tear, ordamage allowswater to enterponton. Any visiblehole will deadlinebay.4~