TM-5-5420-279-10
Table 8.4 Operators PMCS Parallel or Ramp Unit (During)
Location
Item
Not Fully Mission
Procedure
Interval
Item to Check
No.
Capable If:
Service
97
During
Parallel or
Ensure no serious damage to jaws
Excessive damage
ramp unit,
and pinning holes beyond normal
evident.
jaws and
wear and tear. Ensure all jaw
Jaw Pin or R clip
connecting
connecting pins fitted and secured
missing.
pins
with R clip.
98
During
Parallel or
Ensure all shootbolts raised and
Shootbolts not raised
ramp unit,
locked.
and locked.
shootbolts
99
During
Ramp unit end
Ensure end beam fixing pins are
End beam fixing pins
beam, fixing
inserted and in locked position.
missing or unlocked.
pins
100
During
Ramp unit,
Ensure approach ramps fitted
Approach ramps not
approach
correctly and secure. Ensure no
fitted correctly.
ramps
serious damage or distortion
Excessive damage
beyond normal wear and tear.
evident.
Item numbers 101 thru 108 have rolled to next page.