TM-5-5420-279-10
Table 9. 2 Launch Frame Electrical Control Enclosure MIMIC Panel; Indicator lights
(continued)
Indicator
Light
Notes
Checks of Non Normal Status
Normal
Status
Fault
OFF
Indicates a fault signal
The top winch cable has become slack
from the Hydraulic
and the top winch tension indicator has
System.
operated, signified by the TOP WINCH
and the FAULT light flashing. This
This is the same signal as
indication only operates when build
Check Pack "Fault" light.
mode is in HIGH BANK.
Can be cleared by operating chest
pack right hand joystick rearward to re-
tension the top winch cable.
Chest Pack Joystick Failure i.e. Track
Down or out of range.
indicated (2-3 seconds) on initial power
up while the controller sets up and
establishes communication with both
expansion modules (this is normal).
A System Fault identified on Interface
Cabinet Panel.
Minor Fault Light Flashes 4 times a
second.
Check Oil Filters
Check Low Oil Level
Check High Temp Oil
Check Low Temp Oil
Major Fault Light Continuously ON
PTO will cut out and can only be
caused by dangerously low oil level
Low-Low Oil Level.
See Faults as detailed below.
continued
Change 1 9-10.1/(9-10.2 Blank)