TM 5-5420-280-10
0032 00
PREPARATION FOR EMERGENCY MANUAL REMOVAL OF PALLET FROM CBT
(Contd)
NOTE
Perform steps 5 through 7 if pallet hydraulic supply
hoses are connected to CBT.
5. Disconnect pallet hydraulic hoses (17) and (20) from CBT hydraulic pump
hoses (18) and (19), located adjacent to LHS cabinet assembly (12) on late
model CBTs, or at rear of work platform (22) on early model CBTs.
6. Connect CBT hydraulic pump hoses (18) and (19) to LHS hydraulic supply
quick-disconnect couplings (16) and (21), located on bracket (11) on late model
CBTs or bracket (23) on early model CBTs.
7. Connect pallet hydraulic supply hoses (17) and (20) to pallet hydraulic
quick-disconnect couplings (13) and (14), located on pallet A-frame adjacent to
auxiliary reservoir (15).
13
12
14
15
11
21
16
17
16
20
17
18
19
18
23
21
LHS COUPLINGS,
20
LATE MODEL CBT
22
19
LHS COUPLINGS, EARLY MODEL CBT
0032 00-3