NATO SLAVE RECEPTACLE REPLACEMENT
NATO SLAVE RECEPTACLE REPLACEMENT - Continued

Special Tools List For Rapidly Emplaced Bridge (Reb) Page Navigation
  342    343    344    345    346  347  348    349    350    351    352  
img
. .
TM 5-5420-280-23&P
0055 00
NATO SLAVE RECEPTACLE REPLACEMENT (Contd)
REMOVAL
WARNING
Ensure battery ground cable is disconnected or damage to
equipment or injury to personnel may result.
NOTE
Tag all electrical cables and terminals for installation.
1.
Remove screw (7), lockwasher (8), and Launch Power Unit (LPU) starter positive cable (9) from top
terminal (5) of NATO slave receptacle (4). Discard lockwasher (8).
2.
Remove screw (7), lockwasher (8), and main power switch negative jumper cable (10) from bottom
terminal (13) of NATO slave receptacle (4). Discard lockwasher (8).
3.
Remove four nuts (11), screws (1), washers (2), lanyard (14) with attached cover (3), NATO slave
receptacle (4), and gasket (6) from pallet frame (12). Discard gasket (6).
INSTALLATION
1.
Install NATO slave receptacle (4) on pallet frame (12) with new gasket (6), lanyard (14) with
attached cover (3), four washers (2), screws (1), and nuts (11).
2.
Connect main power switch negative jumper cable (10) on bottom terminal (13) of NATO slave
receptacle (4) with new lockwasher (8) and screw (7).
3.
Connect LPU starter positive cable (9) to top terminal (5) with new lockwasher (8) and screw (7).
4.
Connect battery ground cable. Refer to WP 0113 00.
5.
Install bridge halves on bridge pallet. Refer to WP 0018 00.
0055 00-2